Most of our servers have 24 hdds plus 4 ssds.
Any experience how these should be configured to get the best rgw performance?
We have two options:
1) All osds the same, with data on the hdd and block.db on a 40GB
ssd partition
2) Two osd device types: hdd-only for the rgw data pool and
ssd-only for bucket index pool
But all of the bucket index data is in omap, right?
And all of the omap is stored in the rocks db, right?
After reading the recent threads about bluefs slow_used_bytes, I had
the thought that as long as we have a large enough block.db, then
slow_used_bytes will be 0 and all of the bucket indexes will be on
ssd-only, regardless of option (1) or (2) above.
Any thoughts?
Thanks!
Dan